Quantum EC-LLDAA-YF-B Podręcznik Użytkownika Strona 127

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 126
Chapter 8 Logs and Troubleshooting
Autoloader Logs
Quantum SuperLoader 3 User’s Guide 107
00000000:00000000:00000000:00000000
00000000:00000000:00000000:00000000
0002: 2001-Jun-27, 17:38:19.777, Error: 002f0222, Context:
4802/00000000
65460621:00610004:ffffffff:ffffffff
ff741e03:0075ff63:0566063f:007f0000
ffffffff:ffffffff:ffffffff:ffffffff
0003: 2001-Jun-27, 17:38:21.812, Error: c02f0223, Context:
4802/00000000
00000000:00000000:00000000:00000000
00000000:00000000:00000000:00000000
00000000:00000000:00000000:00000000
Time Stamp The time the event occurred. This field helps correlate the event with a
possible application interruption.
If the unit is unable to acquire the correct time/date from the SNTP time
server or the front panel, the time stamp contains values indicating the
power cycle number and the time an entry was written relative to that
power cycle, listed as Power On Hours (POH).
Note: The unit has no internal real-time clock and requires you to set
the time of day from the front panel or the network interface
(SNTP).
Error Fields The error fields are defined as follows:
Recovery Action
Recovery Action defines what the autoloader will do based on the event
that occurred.
Bits 31, 30
Bits
29-28
Bits
27-24
Bits
23-20
Bits
19-16
Bits
15-12
Bits
11-8
Bits
7-4
Bits
3-0
Recovery Action Task ID Error Type Context Information
Przeglądanie stron 126