Chapter 6 Diagnostics
On-board Remote Management Diagnostic Tests
82 Quantum SuperLoader 3 User’s Guide
digit, press Escape. When you have entered the entire six digit
password, you will be asked to press
Enter one more time to
submit the password. If the password is incorrect, you will be
asked to re-enter it using the same procedure. Otherwise, you
will be returned to the
Diagnostics menu. Press Enter to run the
desired test.
The message
Running Test displays while the test is in progress.
To stop the test prematurely, see Stopping a Diagnostic Test
.
b When the test completes, either the message
Test Successful
displays or the message
Test Failed and an error code display.
4 If the test is successful, press
Enter to return to the Diagnostics test
menu. For detailed results of a test, use On-board Remote
Management to retrieve the diagnostic test status (see Diagnostics
Using On-board Remote Management).
On-board Remote Management Diagnostic Tests
You can perform the following diagnostic tests from On-board Remote
Management:
•Loader—Picker Test
• Loader—Magazine Test
• Loader—Inventory Test
•Random Moves
Note: On-board Remote Management allows you to request all
diagnostic tests, but any tests that require a cartridge to be
inserted will time out unless someone manually inserts the
cartridge at the appropriate time.
Diagnostics Using On-
board Remote
Management
To perform diagnostic tests using On-board Remote Management:
1 Open a Web browser and connect to the autoloader. The On-board
Remote Management main menu displays.