Appendix B Fault Symptom Code (FSC) Dictionary
ATL M-Series User’s Guide 113
002D FSC_MAC_ADDR_
ERROR
MAC address could
not be validated and
must be
reprogrammed
Microcode 100%
002E FSC_UNSUPPORTED_FP VAR 1 front panels are
not supported
Microcode 100%
1000 FSC_FPGA_INIT_
STUCK_HI
FPGA INIT pin was
detected as being high
when it should have
been low
System 100%
1001 FSC_FPGA_INIT_NOT_
HI
FPGA INIT pin was
detected as being low
when it should have
been high
System 100%
1002 FSC_FPGA_DONE_
STUCK_HI
FPGA DONE pin was
detected as being high
when it should have
been low
System 100%
1003 FSC_FPGA_DONE_NOT_
HI
FPGA DONE pin was
detected as being low
when it should have
been high
System 100%
2000 FSC_DLT_INIT_FAILED DLT initialization
failed
Microcode 100%
2001 FSC_DRIVE_TIMEOUT_1 Drive time out waiting
for status (drive 1)
Drive 100%
2002 FSC_DRIVE_TIMEOUT_2 Drive time out waiting
for status (drive 2)
Drive 100%
2003 FSC_DRIVE_TIMEOUT_3 Drive time out waiting
for status (drive 3)
Drive 100%
2004 FSC_DRIVE_TIMEOUT_4 Drive time out waiting
for status (drive 4)
Drive 100%
FSC Name Description FRU Name Confidence %