Appendix A Library Specifications
Environmental Specifications
82 Quantum|ATL P3000 Series User’s Guide
Electrical connection
to power
IEC 320 C19 male
connector inside back door
Climatic Environment
Temperature
(operating)
Dry Bulb 15
o
C to 32
o
C (59
o
F to 90
o
F)
Wet bulb 25
o
C (77
o
F) maximum
Thermal transition 11
o
C per hour
Temperature
(shipping and
storage)
Dry bulb -40
o
C to 66
o
C (-40
o
F to
151
o
F)
Wet bulb 46
o
C (115
o
F) maximum
Thermal transition 30
o
C (54
o
F) per hour
Relative
humidity
Operating 20% to 80%, non-
condensing
Shipping and storage 5% to 95%, non-condensing
Electromagnetic/Electrostatic Susceptibility
Altitude Operating Sea Level to 10,000 ft.
(3,048 m)
Shipping and storage Sea Level to 12,000 ft.
(3,657 m)
Heat dissipation Operating 5500 BTU/hr (1400 KCal/
hr or 1600 watts)
Direct ESD Contact discharge @ 2.0, 4.0, 6.0, 8.0 kV to all
external metal panels and
doors
Air discharge @ 2.0, 4.0, 6.0, 8.0, 10.0, 12.0,
15.0 kV to the front GUI
display
Indirect ESD Contact discharge @ 2.0, 4.0, 6.0, 8.0 kV to the