Service Menu 4-153
September 2007
UDS Power
Path: Main Menu Service Diags P/S UDS Power
Use UDS Power to view the status of the installed UDS power
supplies. See Figure 4-238.
Figure 4-238 UDS Power Status Screen
Parameters Description
P/S Drive bay power supply
DC DC output from at least one
power supply
Y= Status Ok
N= No DC output
- = Drive bay not present
x = Invalid power supply
Dual There are two power supplies
to provide power supply
redundancy
Y= Both power supplies are
functioning normally
N= One or both power
supplies failed
- = Drive bay not present
x = Invalid power supply
Rack Rack number. Only racks that
contain UDS drives (CM, DM)
are displayed
P/S:B1 B2 B3 B4
DC :Y Y Y Y
Dual:Y Y Y Y
Rack:04