Chapter 3 System Specifications
Physical Specifications
Scalar i2000 Planning Guide 35
Customer Library
Connection Types and
Speeds 3
Table 6 lists the library connection types and speeds.
Physical Specifications
This section contains the physical specifications for the library modules.
If the library is installed on a raised floor, the raised floor should be
stabilized to prevent any horizontal movement. The library has four point
loads each on the control and expansion modules. See
table 7 on page 36.
Table 6 Library Connections
Types and Speeds
Connection
a
a.The DB-9 serial connection on the management control blade is not intended for customer use.
Connector Speed
Fibre Channel on FC I/O Blade LC 2 gigabit/sec (6404)
4 gigabit/sec (7404)
Fibre Channel on management control blade LC 1 gigabit/sec
Ethernet on management control blade RJ45
10/100 Base-T
SCSI-2 on management control blade 68-pin VHDCI Ultra-2 SCSI
Note
The Scalar i2000 control module-only weight is
approximately 600 lbs. This is the weight of a control
module without packaging or media.