Chapter 4: Configuring the Library
Configuring Control Paths
Quantum Scalar i40 and Scalar i80 User’s Guide 67
application fails, you can manually select a different control path tape
drive for the partition.
Note: You might need to modify settings in your host application as a
result of modifying the control path. See your host application
documentation for more information.
You can only configure control paths via the Web client.
Web Client
1 Select Setup > Control Path.
2 If more than one partition exists, select a partition and click Next.
3 To select a new control path for the partition, select a tape drive
from the list of tape drives.
4 To delete the control path for the partition, locate the tape drive
that is currently selected as the control path and clear the selection.
5 Click Apply.
6 Save the library configuration (see Saving the Library Configuration
on page 106).
Note: You can configure a control path failover drive if you have an
Advanced Reporting license and HP LTO5 tape drives. See
Working with Control Path Failover (CPF) on page 113