Chapter 4 SCSI Commands
MODE SELECT (6) / (10) Command (15h / 55h)
DLT-S4 Interface Reference Guide 152
EnaCleanLight Binary 1 1 When set to 1, the Cleaning Required LED is
turned on and off as appropriate. When set to
0, this functionality is disabled.
EnaCleanSense Binary 1 1 When set to 1, the drive collects cleaning
Sense Key data. When set to 0, this
functionality is disabled.
EnaCleanTA Binary 1 1 When set to 1, the drive returns tape cleaning
flags for TapeAlert. When set to 0, this
functionality is disabled.
EnaGranularity Binary 0 1 Enables the Granularity field in the
READ
BLOCK LIMITS
command.
EnaRepDecomp Binary 0 1 If set and the drive is in Read mode, the
decompression algorithm field in Data
Compression mode is reset if the drive
decompressed the last block the host
requested; otherwise, the drive clears the
Decompression Algorithm field in Data
Compression mode.
EnaSCSIUnlonPMR Binary 0 1 When set to 1, enables a
SCSI UNLOAD when a
previous
PREVENT MEDIUM REMOVAL
command is in effect.
EnaPeriodicClean Binary 1 1 When set to 1, periodic cleaning of the read/
write heads is enabled. When set to 0, this
functionality is disabled.
EnaThirdPtyDens Binary 1 1 When set to 1, makes non-DLT density codes
act as the default density (same as density
code 0).
ForceComp Binary 0 1 0b = Automatic
1
1b = Force Compression disabled
10b = Force Compression enabled
ForceEERebuild Binary 0 1 When set to 1, forces the drive to reset all of
the parameters to default values at the next
power cycle.
Parameter Data Type Default
Length
(Bytes) Usage