10-12
SCSI REFERENCE 1014826
CHAPTER 10—MODE SENSE (1Ah)
Magnum 224 or T24—The library may have up to 24 storage slots. Valid
values for this field are 4 through 24 (18h). The factory default is 18h. The
library ignores the MaxStorAddr field if the MaxStor bit is set to 0. If the
MaxStorAddr field is set to 24 (18h), the library responds as if the MaxStor bit
is set to 0.
StorageLoader 2U—The library may have up to 20 storage slots. Valid values
for this field are 4 through 20 (14h). The factory default is 14h. The library
ignores the MaxStorAddr field if the MaxStor bit is set to 0. If the
MaxStorAddr field is set to 20 (14h), the library responds as if the MaxStor bit
is set to 0.
Magnum 448—The Magnum 448 LTO Library may have up to 48 storage
slots. Valid values for this field are 4 through 48 (30h). The factory default
is 30h. The library ignores the MaxStorAddr field if the MaxStor bit is set to 0.
If the MaxStorAddr field is set to 48 (30h), the library responds as if the
MaxStor bit is set to 0.
Notes:
The MaxStorAddr is a maximum slot count that the library will use. If the count
is less for any reason (I/E Port, Cleaning Slot, a blank magazine without slots) the
smaller number will be used.
The MaxStorAddr field is directly related to the Slot Count option available from
the library’s operator panel. When this field is set, the library only uses the
number of cartridge cells specified as storage elements. The unused cells are not
available for use as addressable storage elements. The number of cells can be
set, cleared, or viewed using the operator panel or by issuing a MODE SELECT
command with this field set to the desired number of cells.
If both the Fixed Cleaning Cell and Auto-Clean flags are set to 1 on the Cleaning
Configuration Page (see page 10-15), the cleaning cell, indicated by the
MaxStorAddr field is used for the cleaning cartridge and is not accessible using
SCSI commands.
The library ignores the MaxStorAddr field if the MaxStor bit is set to 0. If the
MaxStorAddr field is set to 24 (18h), 20 (14h), or 48 (30h), the library responds
as if the MaxStor bit is set to 0.
Changes to the MaxStorAddr field do not take affect until the library is reset.
DisIEP – Byte 05, Bit 6 (Disable I/E Port 1)
This field specifies whether the I/E Port is enabled or disabled.
Magnum 224, T24, or SL 2U—The library has only one I/E Port (I/E Port 1).
0 I/E Port is enabled for use
1 I/E Port is disabled, the slot becomes a storage cell