19-14
SCSI REFERENCE 1014826
CHAPTER 19—REQUEST VOLUME ELEMENT ADDRESS (B5h)
Invert – Byte 09, Bit 6
The library uses single-sided media and does not support inverting of the
media. The value reported for this field is 0.
Source Storage Element Address – Bytes 10 and 11
This field shows the address of the last storage element from which the
cartridge was moved.
Primary Volume Tag Information – Bytes 12 through 47
When the PVolTag field (in the Element Status page described on page 19-5) is
set to 1, this field contains the volume tag (bar code label) information of the
cartridge in the storage location. The library supports eight bytes of volume
tag information, so only the first eight bytes reported are valid.
19.3.7 DATA TRANSFER ELEMENT DESCRIPTOR
The library has the following data transfer elements (tape drives), for which it
returns the following data transfer element descriptor.
Magnum 224, T24, or SL 2U—The library may have one or two tape drives
installed.
Magnum 448—The library may have one, two, three, or four tape drives
installed.
Bit
Byte
7 6 5 4 3 2 1 0
00 (MSB)
Element Address
(LSB)
01
02 Reserved Access Except RSVD Full
03 Reserved
04 Additional Sense Code
05 Additional Sense Code Qualifier
06 RSVD RSVD IDValid LUValid RSVD Logical Unit Number
07 SCSI Bus Address
08 Reserved
09 SValid Invert Reserved
10 (MSB)
Source Storage Element Address
(LSB)
11
Komentarze do niniejszej Instrukcji