PX502 Tape Library Quick Start Guide
10
1 Put on an antistatic wrist strap and clip it to the library
chassis.
2IF there is space above the library to remove the top
cover, remove the twelve PHILLIPS screws securing the
top cover and FlexLink cover to gain further access to
the internal packaging restraints (see figure 17
). If there
is no space above the PX502 library to remove the top
cover, continue with Step 3.
Figure 17 Removing the Top
Cover (Optional Step)
3 When the library powers on for the first time, the OCP
asks you: “Are the internal packaging materials
removed?” (OK or NO).
CAUTION: Take standard ESD precautions when
performing this procedure.
4 Press NO to continue. The system asks you again: “Are
the internal packaging materials removed?” (OK or
NO).
5 Press NO to continue. The OCP displays “Doors opened,
magazines released, pull magazines out before power
shutoff. The library waits approximately 30 seconds for
you to open the doors and remove both magazines
from the library.
6 After the library has powered down, remove the foam
restraints by completing the following steps (see
figure 18
):
a Detach the tie band holding the two sides of the
metal restraints together and remove it from the
library.
b Remove the metal restraints from the library.
c Lift the left foam restraint slightly up and remove it
from the library.
d Slide the right foam restraint to the right until you
are clear of the robotics motor and remove the
restraint from the library.
C
AUTION: Pressing OK when the internal packaging
restraints are in place will damage the library
robotics.
NOTE: If you are unable to remove the magazines before
the library shuts down. Turn on the library power
and repeat the steps above.
C
AUTION: Avoid touching the printed circuit board.
C
AUTION: When removing the foam restraints, ensure
that the robotics umbilical cable is lying
down in the correct position and not across
the robotics track.