SNC 6101 User’s Guide 21
Configuring the SNC 6101
You can configure the SNC 6101 as soon as you have installed it in the Scalar 100 and all appropriate
cables are in place. Configuration defines these values for the SNC 6101:
IP address and subnet mask
gateway address
host name
To cable the service port to your laptop/desktop computer
1 Find the null modem cable supplied with your SNC 6101 (Refer to Unpacking and Inspecting
on page
14).
2 Connect one end of the cable to the DB9 connector on the SNC 6101 that is labeled “null modem.” See
Figure 1
on page 8 for the location.
3 Connect the opposite end of this cable to an available COM port on your laptop/desktop.
To configure HyperTerminal for operation as a service terminal
1 Connect a laptop/desktop computer to the SNC 6101 null modem port with the null modem serial cable
provided. See Figure 10
.
Figure 10 Service Port Connection to a Terminal Device
Note
Configuration requires that you access the SNC 6101 command line interface
by connecting the service port (null modem) on the SNC 6101 to an RS-232
DTE terminal or desktop/laptop computer that is running terminal emulation
software. Most operating systems offer either Windows HyperTerminal or
another default terminal emulation program. The following installation
procedures use HyperTerminal as a sample program.
Note
Procedures for configuring your laptop/desktop as a service terminal are
provided in Configuring the SNC 6101
on page 21.
Note
Configuration commands using the service port are available in the SNC
Firmware 4 User’s Guide.