44 Maintenance
11
At the service terminal, enter the
fcShow command to view the
status of each FC interface that
is installed and connected.
In the output of the fcShow command, look for the
Firmware State column.
12
From the service terminal, enter
the fcShowDevs command to
show the SCSI target devices
that are connected as seen by
the Fibre Channel interface.
Check to see that all SCSI target devices are seen
by each FC interface.
13
Verify that all (or the designated)
target devices are available to
the Host systems.
If the designated devices are NOT available,
reboot the Host and check again.
14
Use the fcShowNames
command and save the
configuration values at a location
easily accessed if the SNC 6101
fails.
For more information on saving the configuration,
refer to the ADIC Management Console User
Guide.
15
Disconnect the RS-232 cable
from the and from the service
terminal.
None.
16
End of repair.
Table 5 Post Replacement Checklist
Step Actions Comments and References
Przeglądanie stron 47