94 Troubleshooting the SAN
• If you do not want to print all the pages of a lengthy event log, click, shift-click and/or control-
click to select the lines you want to print.
• Paste this text into a file editor.
• Select the File menu, then select Print.
Saving a Copy of Currently Displayed Entries
1 Right-click an appliance in the navigation panel or the graphical panel.
2 Select the Events menu, then select Save Event Log.
3 Type a name for the file in the browser dialog box.
If you do not want to save the file to the default location, browse to a new location.
4 After the log is saved, you are asked if you want to clear the event log on the selected appliance.
Select Yes to clear the event log.
Select No to preserve the event log as is.
Interpreting the Event Log
Use Table 4 to interpret listed events. Make a note of pertinent event codes and refer to the SNC Firmware
4 Reference Guide for troubleshooting actions.
If there are no abnormal events, but behavior is still unacceptable, go to Performing Health Check
on page
102.
Table 4 Event Codes and Actions
Event
Code
Description
8 Sense data recorded following a check condition.
Note: Normally, the host system will request and process sense data and then
perform error recovery.
9 LUN reports a “unit attention” condition on a non-removable media device
11 SNC reports a temperature change (event message indicates the change to high,
very high, reduced to high, or OK
13 Appliance is shutting down as requested by AMC
(a Restart was requested)
14 Additional status information used for diagnostics
16 A SCSI bus reports an unexpected interrupt
17 Fibre Channel interface reports a LIP reset was received from a host
18 Fibre Channel interface reports a system error
19 Fibre Channel interface reports an error processing a request
20 Fibre Channel interface reports an error processing a response
21 Appliance processor memory fault detected
22 Fibre Channel interface detected a LIP
Komentarze do niniejszej Instrukcji