ADIC Management Console User’s Guide 95
23 Fibre Channel interface reports a loop up
24 Fibre Channel interface reports a loop down
25 Appliance PCI bus parity error detected
26 Appliance PCI interface error detected
27 A device has been added to a SCSI bus
28 A SCSI bus reports a reset has been detected
29 Appliance has added a device to its configuration table
Note: The trap is delayed until the appliance has been up for 60 seconds.
30 Appliance has removed a device from its configuration
31 Appliance logging service has started
33 An interface has detected a bus fault
(event message indicates the specific interface)
34 An interface has detected a device fault
(event message indicates the specific interface)
35 A SCSI interface reported an unexpected disconnect by a device
36 A parity error was detected on a SCSI bus
37 Fibre Channel port database change detected
39 Directory Server on fabric has changed
40 Maximum LUN limit has been exceeded
41 Fibre Channel transfer failure
Note: Error recovery may have succeeded.
42 Maximum device limit has been exceeded (persistent address map database is full)
43 Fibre Channel interface driver reported debug file dump (event log contains further
information)
58 Power has returned to nominal from warning or alarm stage
59 Power has entered warning range from nominal range (power falling) or alarm range
(power improving)
60 Power has entered alarm range
61 Inlet air, outlet air, or I/O processor temperatures have entered nominal range from a
warning or alarm range
62 Inlet air temperature has entered warning range from nominal range (heating up) or
alarm range (cooling down)
63 Inlet air temperature has entered alarm range
64 Outlet air temperature or I/O processor temperature has entered warning range from
nominal or alarm ranges
Table 4 Event Codes and Actions
Event