134 Troubleshooting and Diagnostics
90h Drive Error
Check Drive
Communication to a drive is
not working, the drive is not
initializing, or the drive is
reporting a problem.
Reboot the system. If the
problem persists, remove the
drive and re-install it. If the
problem still persists, contact
ATAC, you may need to
exchange the drive.
92h DRV Invalid
Call Service
Invalid drive firmware Reload drive firmware or call
ATAC.
94h Drive Media Error Indicates drive media error Remove the suspect tape
EAh Sled Missing
Check Sled
A drive sled has been
removed or is not connected
properly.
Re-insert the sled or check
the connections.
D0h PS Failure
Call Service
A library power supply failed
or is not operating within
specified ranges.
Reboot the system. If the
problem persists, contact
ATAC.
F0h Fan Failure
Call Service
A library or drive fan failed. Prevent the system from
becoming too hot and either
turn off the library or remove
the drive with the bad fan.
Contact ATAC.
80h and
E0h
Obstruction
Check Picker
The picker has reported a
move failure, which may be
caused by an obstruction of
the picker, such as: partially
extended tapes into the
picker path; an ejected tape
from a drive; or a tape within
the picker partially extending
out of the picker.
Try to clear the obstruction.
Contact ATAC.
E7h
E8h
Pick Failed
Clear Picker
Place Failed
Clear Picker
The picker could not get or
put a tape. Typically this
means a tape is still partially
in the picker.
Remove the tape from the
picker. For more information,
see Manual Removal of a
Tape From the Picker on
page 47.
E9h Tape Recovered
to Cell X
Informational message that
indicates that a tape had
been detected in the picker
assembly and was placed in a
slot location (X) to free the
picker and make it
operational.
Make sure that the tape
belongs in the location it was
placed. You may have to use
the Move Media function to
move the tape to the proper
location.
SAC
Code
Error Message Description Recommended Action