140 Specifications
Thermal Environment
Acoustic
Library Interface
Operating Non-operating Shipping & Storage
Dry Bulb
Temperature
10ºC to 38ºC
(50ºF to 100ºF)
@2000 M
10ºC to 33ºC
(50ºF to 91ºF)
@3000 M
10ºC to 45ºC
(50ºF to 113ºF)
-40ºC to 65ºC
(-40ºF to 149ºF)
Temperature
Variation
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
Wet Bulb
Temperature
29ºC (84ºF)
Max
32ºC (90ºF)
Max
37ºC (99ºF)
Max
Relative Humidity 10 to 90% 10 to 90% 10 to 95%
Designation Class 3C Table Top Unit
Upper Limit of Operating Sound Power
a
a. Operating is defined as exercising both robotic and tape drive components.
62 dB (6.2 Bels)
Upper Limit of Idle Sound Power
b
b. Idle mode is defined as the unit being powered on with no robotic or tape drive action.
60 dB (6.0 Bels)
Maximum Operator Position Sound Pressure 61 dB
SCSI The library communicates through external HD 68 pin SCSI connectors
on the Drive Module.
LVD/S
Fibre
Channel
A Fibre Channel interface is provided in an optional Storage
Networking Controller. It supports 50 Micron Multi-Mode Short-wave
and 65 Micron Multi Mode Fibre.
Gigabit
Ethernet
A Gigabit Ethernet interface is provided in an optional Storage
Networking Controller. It supports 3-pair Cat 5e wiring.