144 Specifications
Power
*Power consumption is obtained using RMS values for voltage and current. Drive sled power consumption
is taken while writing to a drive.
Thermal Environment
Input Power 100 – 240 VAC, 50-60 Hz
Power Consumption Typical* W BTU/hr
Library with RMU (no drives or SNC) 27 92.1
LTO-1 drive sled (each) 49 167
LTO-2 drive sled (each) 36 123
LTO-3 drive sled (each) 28 96
SDLT-320 drive sled (each) 35 120
SDLT-600 drive sled (each) 46 157
SNC4000 49 167.2
SNC4501 17.4 59.4
Operating Non-operating Shipping & Storage
Dry Bulb
Temperature
10ºC to 38ºC
(50ºF to 100ºF)
@2000 M
10ºC to 33ºC
(50ºF to 91ºF)
@3000 M
10ºC to 45ºC
(50ºF to 113ºF)
-40ºC to 65ºC
(-40ºF to 149ºF)
Temperature
Variation
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
Wet Bulb
Temperature
29ºC (84ºF)
Max
32ºC (90ºF)
Max
37ºC (99ºF)
Max
Relative Humidity 10 to 90% 10 to 90% 10 to 95%