MODE SENSE (6) / (10) Command (1Ah / 5Ah) SDLT 600 SCSI Interface Guide
4-112 January 2005 81-81200-02 REV A01
Table 4-62. MODE SENSE Block Descriptor — Field Descriptions
Field
Name
Description
Density
Code
Matches the current tape medium density.
Density
Code Description
00h Default density
48h 133,000 bpi, 56 logical tracks, serial cartridge tape
110.0 GB / 220.0 GB (Super DLTtape I)
49h 190,000 bpi, 56 logical tracks, serial cartridge tape
160.0 GB / 320.0 GB (Super DLTtape I)
4Ah 233,000 bpi, 40 logical tracks, serial cartridge tape
300.0 GB / 600.0 GB (Super DLTtape II)
50h 175,000 bpi, 60 logical tracks, serial cartridge tape
80.0 GB / 160.0 GB (VStape I)
Number
of
Blocks
Set to 0, indicating that all of the remaining logical blocks on the tape have the
medium characteristics specified by the block descriptor.
Block
Length
Specifies the length in bytes of each logical block transferred over the SCSI bus. A
block length of 0 indicates that the length is variable, as specified in the I/O
command. Any other value indicates the number of bytes per block that are used for
READ, WRITE, and VERIFY type commands that specify a fixed bit of 1 (Fixed
Block Mode).