Quantum 1200 Series DAT Autochanger Podręcznik Użytkownika Strona 273

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 294
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 272
SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-231
A reservation with the RESERVE UNIT command remains in effect until one of the following
conditions is met:
Another valid RESERVE UNIT command from the initiator supersedes it.
A RELEASE UNIT command from the same initiator releases it.
A TARGET RESET message from any initiator releases it.
A reset condition releases it.
The occurrence of the last two conditions is indicated by the drive returning a CHECK CONDITION
status, Sense Key set to UNIT ATTENTION on the next command following the condition. It is not an
error to issue a RESERVE UNIT command to a drive that is currently reserved by the requesting
initiator.
If another initiator has previously reserved the drive, the drive returns a RESERVATION CONFLICT
status.
If, after honoring the reservation, any other initiator attempts to perform any command except
INQUIRY, REQUEST SENSE, or RELEASE UNIT, the drive rejects the command with a
RESERVATION CONFLICT status. That drive ignores a RELEASE UNIT command issued by
another initiator.
An initiator that holds a current reservation may modify that reservation—for example, to switch third
parties—by issuing another RESERVE UNIT command to the drive.
Przeglądanie stron 272
1 2 ... 268 269 270 271 272 273 274 275 276 277 278 ... 293 294

Komentarze do niniejszej Instrukcji

Brak uwag